Detroit Diesel
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3490 FMI 5 (ACM) Post Run Indicator Lamp
Posted by PerDiezel Solutions on
NOTE: Post Run Indicator Lamp – Indicated a short to ground on pin 14 circuit of the aftertreatment control module 120-pin connector. Repair the short to ground on pin 14 circuit of the aftertreatment control module (ACM) 120-pin connector. NOTE: Repair the open circuit on pin 14 of the ACM2.1 120-pin connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3509 FMI 3 (ACM) The 5V Sensor Supply Bank 1 Circuit Failed High
Posted by PerDiezel Solutions on
DESCRIPTION:5V sensor supply bank 1 circuit failed high. MONITORED PARAMETER:Aftertreatment Control Module (ACM) 5V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Engine Idle: One minute. PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.3. Pin 103, inlet air delta p & intake throttle valve.4. Pin 117, inlet air delta p & intake throttle valve.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3509 FMI 3 (MCM) 5V Sensor Supply Bank 1 Circuit Failed High
Posted by PerDiezel Solutions on
DESCRIPTION:This code sets when the motor control module (MCM) detects a short to voltage on pins 58 or 117. MONITORED PARAMETER:5V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Engine Idle: One minute. PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.3. Pin 103, inlet air delta p & intake throttle valve.4. Pin 117, inlet air delta p & intake throttle valve.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3509 FMI 4 (ACM) The 5V Sensor Supply Bank 1 Circuit Failed Low
Posted by PerDiezel Solutions on
DESCRIPTION:5V sensor supply bank 1 circuit failed low. MONITORED PARAMETER:Aftertreatment Control Module (ACM) 5V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Engine Idle: One minute. PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3509 FMI 4 (MCM) 5V Sensor Supply Bank 1 Circuit Failed Low
Posted by PerDiezel Solutions on
DESCRIPTION:This code sets when the motor control module (MCM) detects a short to ground on pins 58 or 117. MONITORED PARAMETER:5V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Engine Idle: One minute. PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.