25% Discount for payments with Crypto Currency



Eaton

Eaton Gen 1 (AutoShift) Fault Code: 58 PID: PID 191 FMI: 2 Output Shaft Speed Sensor

Posted by PerDiezel Solutions on

Overview:This code indicates an electrical problem in the output shaft speed sensor circuit. The signal from the sensor did not match the current operating conditions. Detection:A Speed Sensor is determined faulty when all Speed Sensor readings are compared and one sensor is inconsistent. Fallback:This fault causes a 5-speed fallback and the transmission stays in either LO range or HI range. When the vehicle comes to a stop, an attempt to shift into LO range is made. The fallback causes a 1-speed fallback on transmissions with no auxiliary section. Required Tools:1) Basic Hand Tools2) Digital Volt/Ohm Meter3) AutoSelect/AutoShift Troubleshooting Guide Possible...

Read more →


Eaton Gen 1 (AutoShift) Fault Code: 61 PID: SID 39 FMI: 5 Rail Select Motor

Posted by PerDiezel Solutions on

Overview:This code indicates an electrical failure of the rail select motor that drives the electric shifter. Detection:Starting at key-on and throughout operation, the Transmission Controller constantly measures the motor circuit. Failure mode of short to battery, short to ground, or open circuit is detected. The Transmission Controller also monitors the amount of current required to drive the motors. If the over current limit is exceeded, the fault code is also set. Fallback:This fault causes an In Place fallback. Required Tools:1) Basic Hand Tools2) Digital Volt/Ohm Meter3) AutoSelect/AutoShift Troubleshooting Guide Possible Causes:1) Failed rail select motor2) Malfunctioning transmission ECU3) Power Interface...

Read more →


Eaton Gen 1 (AutoShift) Fault Code: 61 PID: SID 39 FMI: 6 Rail Select Motor

Posted by PerDiezel Solutions on

Overview:This code indicates an electrical failure of the rail select motor that drives the electric shifter. Detection:Starting at key-on and throughout operation, the Transmission Controller constantly measures the motor circuit. Failure mode of short to battery, short to ground, or open circuit is detected. The Transmission Controller also monitors the amount of current required to drive the motors. If the over current limit is exceeded, the fault code is also set. Fallback:This fault causes an In Place fallback. Required Tools:1) Basic Hand Tools2) Digital Volt/Ohm Meter3) AutoSelect/AutoShift Troubleshooting Guide Possible Causes:1) Failed rail select motor2) Malfunctioning transmission ECU3) Power Interface...

Read more →


Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 5 Gear Select Motor

Posted by PerDiezel Solutions on

Overview:This code indicates an electrical failure of the gear select motor that drives the electric shifter. Detection:Starting at key-on and throughout operation, the Transmission Controller constantly measures the motor circuit. Failure mode of short to battery, short to ground, or open circuit is detected. The Transmission Controller also monitors the amount of current required to drive the motors. If the over current limit is exceeded, the fault code is also set. Fallback:This fault causes an In Place fallback. Required Tools:1) Basic Hand Tools2) Digital Volt/Ohm Meter3) AutoSelect/AutoShift Troubleshooting Guide Possible Causes:1) Failed gear select motor2) Malfunctioning transmission ECU Eaton Gen...

Read more →


Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 6 Gear Select Motor

Posted by PerDiezel Solutions on

Overview:This code indicates an electrical failure of the gear select motor that drives the electric shifter. Detection:Starting at key-on and throughout operation, the Transmission Controller constantly measures the motor circuit. Failure mode of short to battery, short to ground, or open circuit is detected. The Transmission Controller also monitors the amount of current required to drive the motors. If the over current limit is exceeded, the fault code is also set. Fallback:This fault causes an In Place fallback. Required Tools:1) Basic Hand Tools2) Digital Volt/Ohm Meter3) AutoSelect/AutoShift Troubleshooting Guide Possible Causes:1) Failed gear select motor2) Malfunctioning transmission ECU Eaton Gen...

Read more →


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.