Eaton Fuller Advantage (2017) Fault Code: 96 PID: TBH SPN: FMI: 3 ECA Battery Voltage Gen2 ECA: Voltage Above Normal or Shorted High
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage transmission is equipped with an Electric Clutch Actuator (ECA) that controls the position of the clutch assembly. The ECA operates on a non-switched battery power supply.Fault Code 96 indicates battery power to the ECA is outside of the acceptable ECA operating range, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses. Note: The troubleshooting procedure for Fault Code 66 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 96 was not...
Eaton Fuller Advantage (2017) Fault Code: 96 PID: TBH SPN: FMI: 4 ECA Battery Voltage Gen2 ECA: Voltage Below Normal or Shorted Low
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage transmission is equipped with an Electric Clutch Actuator (ECA) that controls the position of the clutch assembly. The ECA operates on a non-switched battery power supply.Fault Code 96 indicates battery power to the ECA is outside of the acceptable ECA operating range, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses. Note: The troubleshooting procedure for Fault Code 66 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 96 was not...
Eaton Fuller Advantage (2017) Fault Code: 99 PID: SPN: 781 FMI: 14 Direction Mismatch: Special Instructions
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage transmission uses the X-Y Shifter to select the proper rail and engage or disengage a gear based on the driver’s selected mode of operation. The position of the X-Y Shift Finger is controlled and monitored by the Transmission Electronic Control Unit (TECU) by way of the X-Y Gear Position and Rail Position Sensors. Fault Code 99 is set when the TECU commands the X-Y Shifter to move to a specific position and the reported Shift Finger position achieved does not match the desired position. Detection:This fault can only be detected when there are no failures of the...
Eaton Fuller Advantage (2017) Fault Code: 99 PID: SID 58 SPN: FMI: 14 Direction Mismatch: Special Instructions
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage transmission uses the X-Y Shifter to select the proper rail and engage or disengage a gear based on the driver’s selected mode of operation. The position of the X-Y Shift Finger is controlled and monitored by the Transmission Electronic Control Unit (TECU) by way of the X-Y Gear Position and Rail Position Sensors. Fault Code 99 is set when the TECU commands the X-Y Shifter to move to a specific position and the reported Shift Finger position achieved does not match the desired position. Detection:This fault can only be detected when there are no failures of the...