Detroit Diesel

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3841 FMI 3 (CPC) Frequency Output 4 11 – Failed High on Pin 11 Circuit of the Common Powertrain Controller #4 Connector

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 11 of the CPC4 #4 connector.

Read more →


Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3841 FMI 4 (CPC) Frequency Output 4 11 – Indicated By a Short to Ground on Pin 11 Circuit of the Common Powertrain Controller #4 Connector

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 11 of the CPC4 #4 connector.

Read more →


Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3841 FMI 5 (CPC) Frequency Output 4 11 – Indicated By an Open Circuit on Pin 11 Circuit of the Common Powertrain Controller #4 Connector

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 2 of the CPC4 #4 connector.

Read more →


Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3842 FMI 3 (CPC) Analog Ground 3 02 Circuit Failed High on Pin 2 Circuit of the Common Powertrain Controller #3 Connector

Posted by PerDiezel Solutions on

NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 2 of the CPC4 #3 connector.

Read more →


Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3842 FMI 4 (CPC) Analog Ground 3 02 Circuit Failed Low on Pin 2 Circuit of the Common Powertrain Controller #3 Connector

Posted by PerDiezel Solutions on

NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 2 of the CPC4 #3 connector.

Read more →