Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 31 (MCM, CPC) Starter Jammed (Tooth to Tooth Jam)

Posted by PerDiezel Solutions on

NOTE: This fault code indicates the starter teeth have not engaged correctly into the flywheel (jammed). NOTE: Attempt to start the engine. If the engine starts correctly, attempt to start the engine three times. If the fault does not re-occur, clear code and release vehicle. The starter may not engage the flywheel. POSSIBLE CAUSES:1. Starter motor alignment.2. Starter drive damage.3. Incorrect starter installed.4. Flywheel damage. NOTE: This fault indicates the starter teeth have not engaged correctly to the flywheel (jammed). PROBABLE CAUSES:1. Starter motor alignment.2. Starter drive damage.3. Incorrect starter installed.4. Flywheel damage.

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 4 (MCM, CPC) Engine Starter Relay Circuit Failed Low

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. PROBABLE CAUSES:1. Starter relay.2. Starter relay wiring.

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 5 (MCM) Engine Starter Relay Open Circuit

Posted by PerDiezel Solutions on

DESCRIPTION:

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 7 (MCM, CPC) Engine Starter Relay Jammed

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. PROBABLE CAUSES:1. Starter relay.2. Starter relay wiring.

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 679 FMI 7 (MCM) Pressure Limiting Valve (PLV) Staying Open

Posted by PerDiezel Solutions on

NOTE: The pressure limiting valve will open when rail pressure is above 1150 bar. The motor control module (MCM) will command a lower rail pressure trying to force the pressure limiting valve closed. If the pressure limiting valve does not close, a fault code is generated. The condition that caused the PLV to open must be addressed. DESCRIPTION:1. Pressure limiting valve.2. Failed to close. MONITORED PARAMETER:Pressure limiting valve. TYPICAL ENABLING CONDITIONS:10 seconds MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:10 seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:Engine Idle: One minute. NOTE: The PLV will open with...