25% Discount for payments with Crypto Currency



Detroit Diesel

Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2659 FMI 0 (MCM) Exhaust Gas Recirculation Flow Target Error (High Flow)

Posted by PerDiezel Solutions on

DESCRIPTION:Exhaust Gas Recirculation (EGR) flow target error diagnostic – high flow. MONITORED PARAMETER:EGR Mass Flow TYPICAL ENABLING CONDITIONS:1. Desired EGR mass flow greater than .08.2. EGR in closed loop control.3. Charge air cooler (CAC) outlet temperature greater than 0°C (32°F).4. Engine speed 1080-2500 rpm.5. Engine torque 200 to 2500 N·m (148 to 1844 abaft).6. Coolant temperature greater than 65°C (149°F).7. Ambient temperature greater than -8°C (18°F) ambient.8. Barometric pressure greater than 755 mbar. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:20 DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:1. Start engine.2. Warm up such that coolant temperature greater than 65°C (149°F).3....

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2659 FMI 1 (MCM) Exhaust Gas Recirculation Flow Target Error (Low Flow)

Posted by PerDiezel Solutions on

NOTE: If codes 441-xx, 1636-xx, 2791-xx, 3563-xx, or 2630-xx are active, fix those first. PROBABLE CAUSES:1. Inspect the EGR and exhaust system for evidence of leaking.2. Delta P sensor.3. Delta P sensor ports.4. Delta P sensor harness/connector.5. Air inlet manifold pressure sensor.6. Air inlet manifold pressure sensor connector/harness.7. Remove the EGR cooler hot pipe, EGR crossover pipe, and the delivery pipe for excessive build up or blockage.8. EGR valve failure.

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 10 (MCM) Exhaust Gas Recirculation Actuator Slow Response

Posted by PerDiezel Solutions on

DESCRIPTION:Exhaust Gas Recirculation (EGR) Actuator Slow Response. MONITORED PARAMETER:EGR Mass Flow Gradient. TYPICAL ENABLING CONDITIONS:1. EGR in Closed-Loop Control.2. EGR Flow Must Vary, CAC Outlet Temperature greater than 0°C (32°F).3. Engine Speed 1200 to 2500 rpm, Engine Torque 500 to 2500 N·m.4. Coolant Temperature greater than 65°C (149°F).5. Ambient Temperature Greater Than -8°C (17.6°F) Ambient.6. Barometric Pressure Greater Than 755 mbar.7. Engine must have not been in regeneration mode for greater than Five minutes. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always Enabled TYPICAL DURATION:Five Seconds DASH LAMPS:MIL ENGINE REACTION:None VERIFICATION:1. When ambient temperature greater than -8°C (17.6°F).2. Barometric pressure greater than 755 mbar.3....

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 11 (MCM) Exhaust Gas Recirculation Actuator Restricted Operability

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. PROBABLE CAUSES:1. If any voltage codes exist, fix those first.2. EGR valve actuator pull rod.3. EGR actuator.4. EGR valve.5. Wiring between the EGR actuator harness and the ECM.6. ECM failure.

Read more →


Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 14 (MCM) Exhaust Gas Recirculation Valve Actuator Failsafe Mode, Motor ON

Posted by PerDiezel Solutions on

NOTE: Please see the step by step troubleshooting procedures for this specific code. PROBABLE CAUSES:1. If any voltage codes exist, fix those first.2. EGR valve actuator pull rod.3. EGR actuator.4. EGR valve.5. Wiring between the EGR actuator harness and the ECM.6. ECM failure.