Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known

Posted by PerDiezel Solutions on

Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank. Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system. Component LocationThe aftertreatment intake NOx sensor is mounted on the engine...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system. Component LocationThe aftertreatment intake NOx sensor is mounted on the engine...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system. Component LocationThe aftertreatment outlet NOx sensor location can vary...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system. Component LocationThe aftertreatment outlet NOx sensor location can vary...