Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4728 PID: SPN: 1209 FMI: 18 Exhaust Gas Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Posted by PerDiezel Solutions on

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold. The exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4731 PID: SPN: 3031 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Out of Calibration

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank. Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the SAE J1939 datalink message received...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level inside the aftertreatment diesel exhaust fluid tank. Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the SAE J1939 datalink message received from...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known

Posted by PerDiezel Solutions on

Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank. Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level inside the aftertreatment diesel exhaust fluid tank. Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThe aftertreatment diesel exhaust fluid tank level sensor reported an unknown error. Action...