Eaton
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection:The TECU monitors...
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X Y Shifter. Detection:The TECU...
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection:The TECU monitors...
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via theTransmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection:The TECU monitors both...
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Posted by PerDiezel Solutions on
Overview:The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via theTransmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection:The TECU monitors both...