Detroit Diesel
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3861 FMI 3 (CPC) Digital Input 4 13 – Failed High on Pin 13 Circuit of the Common Powertrain Controller #4 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 13 of the CPC4 #4 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3861 FMI 4 (CPC) Digital Input 4 13 – Short to Ground on Pin 13 Circuit of the Common Powertrain Controller #4 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 13 of the CPC4 #4 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3862 FMI 3 (CPC) Digital Input 1 10 – Failed High on Pin 10 Circuit of the Common Powertrain Controller #1 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 10 of the CPC4 #1 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3862 FMI 4 (CPC) Digital Input 1 10 – Short to Ground on Pin 10 Circuit of the Common Powertrain Controller #1 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 10 of the CPC4 #1 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3863 FMI 3 (CPC) Digital Input 4 17 – Failed High on Pin 17 Circuit of the Common Powertrain Controller #4 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 17 of the CPC4 #4 connector.