Detroit Diesel
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3853 FMI 4 (CPC) Digital Input 2 12 – Short to Ground on Pin 12 Circuit of the Common Powertrain Controller #2 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 12 of the CPC4 #2 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3854 FMI 3 (CPC) Digital Input 2 13 – Failed High on Pin 13 Circuit of the Common Powertrain Controller #2 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 13 of the CPC4 #2 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3854 FMI 4 (CPC) Digital Input 2 13 – Short to Ground on Pin 13 Circuit of the Common Powertrain Controller #2 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 13 of the CPC4 #2 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3855 FMI 3 (CPC) Digital Input 2 14 – Failed High on Pin 14 Circuit of the Common Powertrain Controller #2 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 14 of the CPC4 #2 connector.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3855 FMI 4 (CPC) Digital Input 2 14 – Short to Ground on Pin 14 Circuit of the Common Powertrain Controller #2 Connector
Posted by PerDiezel Solutions on
NOTE: The common powertrain controller (CPC) digital outputs have the same SPN as some motor control module (MCM) faults. NOTE: If ECM has been programmed recentely, check programming to ensure it is correct. NOTE: Otherwise, fix the open circuit on pin 14 of the CPC4 #2 connector.