cumminz
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4149 PID: SPN: 2623 FMI: 8 Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency- Abnormal frequency or Pulse width or Period
Posted by PerDiezel Solutions on
Circuit DescriptionThe accelerator pedal contains two position sensors. These position sensors are used to measure the throttle position. Both position sensors receive a 5 volt supply from the ECM. A corresponding signal voltage based on the position of the accelerator pedal is then received from the ECM. The signal voltage for accelerator position 1 is twice as much as the signal voltage from the accelerator position 2. Component LocationThe accelerator pedal or lever position sensor is mounted to the accelerator pedal assembly. Refer to the OEM service manual. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 415 PID: PID 100 SPN: 100 FMI: 1 Engine Oil Rifle Pressure- Data Valid But Below Normal Operational Range- Most Severe Level
Posted by PerDiezel Solutions on
Circuit DescriptionAn engine oil pressure switch or oil pressure sensor is used by the engine control module (ECM) to monitor the lubricating oil pressure. For engines with an oil pressure switch, the switch is normally closed when the engine is not running and open when oil pressure is present. For engines with an oil pressure sensor, the ECM will detect a low signal voltage at operating conditions when the oil pressure is low. The ECM will detect a high signal voltage at operating conditions when the oil pressure is high. Component LocationThe engine oil pressure sensor is located in the...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4151 PID: SPN: 5742 FMI: 9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Abnormal Update Rate
Posted by PerDiezel Solutions on
Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4152 PID: SPN: 5743 FMI: 9 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Abnormal Update Rate
Posted by PerDiezel Solutions on
Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually. Component LocationThe aftertreatment SCR temperature sensor module is mounted on...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4153 PID: SPN: 7321 FMI: 3 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Posted by PerDiezel Solutions on
Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system. Component LocationThe aftertreatment particulate matter sensor location can vary depending on...