cumminz
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 386 PID: SID 212 SPN: 3509 FMI: 3 Sensor Supply 1 Circuit- Voltage Above Normal or Shorted to High Source
Posted by PerDiezel Solutions on
Circuit DescriptionThe sensor supply 1 circuit of the engine control module (ECM) provides a 5 volt supply to various sensors on the engine harness. Refer to the wiring diagram for sensor supply identification. Component LocationSensor Supply 1 originates in the Engine Wiring Harness portion of the ECM. It supplies 5 volts to sensors in the engine wiring harness. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 1 signal voltage was greater than...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3867 PID: SPN: 3364 FMI: 18 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Below Normal Operating Range- Moderately Severe Level
Posted by PerDiezel Solutions on
Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank. Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3868 PID: SPN: 3364 FMI: 9 Aftertreatment Diesel Exhaust Fluid Quality- Abnormal Update Rate
Posted by PerDiezel Solutions on
Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank. Component LocationThe DEF quality sensor is typically mounted in the DEF tank or in-line with the DEF dosing unit supply line. Reference the OEM service manual for a...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3878 PID: SPN: 3364 FMI: 2 Aftertreatment Diesel Exhaust Fluid Quality- Data Erratic, Intermittent, or Incorrect
Posted by PerDiezel Solutions on
Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank. Component LocationThe DEF quality sensor is typically mounted in the DEF tank or in-line with the DEF dosing unit supply line. Reference the OEM service manual for a...
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3899 PID: SPN: 5848 FMI: 4 Aftertreatment 1 SCR Intermediate NH3 Sensor- Voltage Below Normal or Shorted to Low Source
Posted by PerDiezel Solutions on
Circuit DescriptionThe aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system. Component LocationThe aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst. Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR intermediate temperature has been above 170 C [338...