CAT
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 02 PID: 244 SPN: FMI: 2 Event Recorder Data Lost
Posted by PerDiezel Solutions on
The ECM detects the following conditions: •The unswitched battery connection has been disconnected from the ECM. Probable Causes: 1) ECM Connection/harness2) Battery voltage at ECM3) Truck battery or battery cable issue4) Aftermarket engine protection switch5) ECM Failure CAT 3406E (Prefix 5DS or 1LW) Fault Code: 01 PID: 71 SPN: FMI: 0 Idle Shutdown Override CAT 3406E (Prefix 5DS or 1LW) Fault Code: 00 PID: 171 SPN: FMI: 11 Ambient Air Temperature Data Lost CAT 3406E (Prefix 5DS or 1LW) Fault Code: 00 PID: 171 SPN: FMI: 4 Ambient Air Temperature voltage low CAT 3406E (Prefix 5DS or 1LW) Fault Code:...
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 12 PID: 111 SPN: FMI: 2 Coolant Level signal invalid
Posted by PerDiezel Solutions on
The ECM detects the following conditions: •The coolant level sensor is sending an invalid signal for more than ten seconds.•The “Coolant Level Sensor” parameter is programmed to “Yes”. Probable Causes: 1) ECM Connection/Harness2) Coolant sensor failure3) Coolant sensor harness failure4) ECM Failure CAT 3406E (Prefix 5DS or 1LW) Fault Code: 02 PID: 244 SPN: FMI: 2 Event Recorder Data Lost CAT 3406E (Prefix 5DS or 1LW) Fault Code: 01 PID: 71 SPN: FMI: 0 Idle Shutdown Override CAT 3406E (Prefix 5DS or 1LW) Fault Code: 00 PID: 171 SPN: FMI: 11 Ambient Air Temperature Data Lost CAT 3406E (Prefix 5DS...
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 13 PID: 174 SPN: FMI: 3 Fuel Temperature voltage high
Posted by PerDiezel Solutions on
The Engine Control Module (ECM) detects the following conditions: •The signal voltage from the fuel temperature sensor is greater than 4.95 VDC for more than eight seconds. Probable Causes: 1) ECM Connection/Harness2) If code 232-3 or 232-4 (5 Volt Supply voltage codes) are active, troubleshoot those instead3) Temperature sensor failure4) Temperature sensor harness5) ECM Failure CAT 3406E (Prefix 5DS or 1LW) Fault Code: 12 PID: 111 SPN: FMI: 2 Coolant Level signal invalid CAT 3406E (Prefix 5DS or 1LW) Fault Code: 02 PID: 244 SPN: FMI: 2 Event Recorder Data Lost CAT 3406E (Prefix 5DS or 1LW) Fault Code: 01...
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 13 PID: 174 SPN: FMI: 4 Fuel Temperature voltage low
Posted by PerDiezel Solutions on
The Engine Control Module (ECM) detects the following conditions: •The signal voltage from the fuel temperature sensor is less than 0.2 VDC for more than eight seconds. Probable Causes: 1) ECM Connection/Harness2) If code 232-3 or 232-4 (5 Volt Supply voltage codes) are active, troubleshoot those instead3) Temperature sensor failure4) Temperature sensor harness5) ECM Failure CAT 3406E (Prefix 5DS or 1LW) Fault Code: 13 PID: 174 SPN: FMI: 3 Fuel Temperature voltage high CAT 3406E (Prefix 5DS or 1LW) Fault Code: 12 PID: 111 SPN: FMI: 2 Coolant Level signal invalid CAT 3406E (Prefix 5DS or 1LW) Fault Code: 02...
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 14 PID: 121 SPN: FMI: 5 Low/High Retarder current low
Posted by PerDiezel Solutions on
The Engine Control Module (ECM) detects the following conditions: •The ECM detects a low current condition (open circuit) for one second while the ECM is attempting to energize the solenoid for cylinders 3 and 4.•The engine retarder switch is in the low or high position. Probable Causes: 1) ECM Connection/Harness2) Harness between the ECM and valve cover base3) Engine retarder solenoid failure4) Harness under valve cover5) ECM Failure6) Harness at bulkhead connector CAT 3406E (Prefix 5DS or 1LW) Fault Code: 13 PID: 174 SPN: FMI: 4 Fuel Temperature voltage low CAT 3406E (Prefix 5DS or 1LW) Fault Code: 13 PID:...