Volvo All Engines (2010 Emissions) Fault Code: SPN 3250 FMI 1 PID: DPF Spark Assisted Flame Temperature Sensor

Posted by PerDiezel Solutions on

This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set. Conditions for diagnostic trouble code (DTC):1) Multiple lost...

Read more →


Volvo All Engines (2010 Emissions) Fault Code: SPN 3250 FMI 13 PID: DPF Spark Assisted Flame Temperature Sensor

Posted by PerDiezel Solutions on

This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set. Conditions for diagnostic trouble code (DTC):1) Flame temperature:...

Read more →


Volvo All Engines (2010 Emissions) Fault Code: SPN 3250 FMI 14 PID: DPF Spark Assisted Flame Temperature Sensor – Least Severe Level

Posted by PerDiezel Solutions on

This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set. Conditions for diagnostic trouble code (DTC):1) Lost flame...

Read more →


Volvo All Engines (2010 Emissions) Fault Code: SPN 3250 FMI 2 PID: DPF Spark Assisted Flame Temperature Sensor

Posted by PerDiezel Solutions on

This diagnostic trouble code (DTC) indicates malfunction at the aftertreatment diesel particulate filter (DPF) flame temperature sensor. This aftertreatment DPF flame temperature sensor is used to measure engine exhaust gas temperature (EGT) within the flame region of the aftertreatment DPF during aftertreatment DPF regeneration. The aftertreatment control module (ACM) monitors this temperature to detect the existence of the flame. Diagnostic trouble codes (DTCs) may result if the system is unable to light the flame or if there are multiple flame losses. Aftertreamemt DPF regeneration will be prevented until the system is sufficiently warmed-up for the specified duration. Conditions for diagnostic...

Read more →


Volvo All Engines (2010 Emissions) Fault Code: SPN 3250 FMI 3 PID: DPF Spark Assisted Flame Temperature Sensor

Posted by PerDiezel Solutions on

This diagnostic trouble code (DTC) indicates malfunction at the aftertreatment diesel particulate filter (DPF) flame temperature sensor. This aftertreatment DPF flame temperature sensor is used to measure engine exhaust gas temperature (EGT) within the flame region of the aftertreatment DPF during aftertreatment DPF regeneration. The aftertreatment control module (ACM) monitors this temperature to detect the existence of the flame. Diagnostic trouble codes (DTCs) may result if the system is unable to light the flame or if there are multiple flame losses. Aftertreamemt DPF regeneration will be prevented until the system is sufficiently warmed-up for the specified duration. Conditions for diagnostic...