Overview:
Fault Code 42 indicates the transmission is unable to complete a shift across the Splitter. The Splitter is either stuck in HI or LO, or cannot complete engagement into HI or LO.

Detection:
The transmission attempts the same splitter shift 5 consecutive times and determines the shift cannot be completed based on the speeds across the back box.

Fallback:
This fault causes a 9-speed fallback and the transmission stays in either LO split or HI split.

Possible Causes:
1) Low air pressure
2) Contaminated air supply
3) Air leak
4) Splitter valve
5) Splitter Actuator, Cylinder, Piston or Yoke

Shop Talk:
Operate vehicle and perform several range up shifts and down shifts. The failure is detected after 5 consecutive attempts to complete the same type of range shift. Several shifts (10 or more) may be necessary before the controller confirms the failure.

Eaton Gen 2 (AutoShift) Fault Code: 42 PID: SID 61 FMI: 7 Splitter failed to Engage
Eaton Gen 2 (AutoShift) Fault Code: 41 PID: SID 56 FMI: 7 Range Failed to Engage
Eaton Gen 2 (AutoShift) Fault Code: 35 PID: SID 231 FMI: 2 J1939 Data Link
Eaton Gen 2 (AutoShift) Fault Code: 33 PID: 168 FMI: 4 Battery Voltage Supply
Eaton Gen 2 (AutoShift) Fault Code: 32 PID: SID 62 FMI: 4 Switched Voltage Supply
Eaton Gen 2 (AutoShift) Fault Code: 31 PID: SID 218 FMI: 4 Momentary Ignition Interrupt Relay

PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.