25% Discount for payments with Crypto Currency



Detroit DD16 GHG14 (2014-16) Fault Code: SPN 4374 FMI 3 (ACM) Diesel Exhaust Fluid (DEF) Pump Speed Signal Above Measurement Range

Posted by PerDiezel Solutions on

DESCRIPTION:
DEF pump speed signal above measurement range.

MONITORED PARAMETER:
DEF pump speed frequency.

TYPICAL ENABLING CONDITIONS:
1. DEF pump enabled.
2. On-Off-Cycle request.

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
2 minutes

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 10%

VERIFICATION:
SCR ADS Self-Check.

NOTE: If any other codes active, fix those first.

PROBABLE CAUSES:
1. Inspect the DEF pump connector/harness.
2. DEF pump failure.
3. ACM (Aftertreament Control Module ECM) failure.


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.