25% Discount for payments with Crypto Currency



Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed Low

Posted by PerDiezel Solutions on

NOTE: This code sets when the common powertrain controller (CPC) detects the voltage on the sensor supply circuits is out of range.

DESCRIPTION:
Remote accelerator pedal supply voltage circuit failed low.

MONITORED PARAMETER:
Remote accelerator pedal voltage.

TYPICAL ENABLING CONDITIONS:
Always on

MONITOR SEQUENCE:
Key on

EXECUTION FREQUENCY:
None

TYPICAL DURATION:
None

DASH LAMPS:
CEL

ENGINE REACTION:
Idle only

VERIFICATION:
1. Ignition key
2. Cycle on

POSSIBLE CAUSES:
1. Remote accelerator pedal assembly.
2. Circuit fault.
3. Fault within the CPC.
4. Improper configuration of the CPC.

NOTE: This code always indicates to replace the MCM.


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.