25% Discount for payments with Crypto Currency



Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3480 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Sensor – Failed Self Test

Posted by PerDiezel Solutions on

DESCRIPTION:
Hydrocarbon (HC) doser fuel line pressure (FLP) sensors-failed self test.

MONITORED PARAMETER:
Doser fuel line pressure.

TYPICAL ENABLING CONDITIONS:
Dosing enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
One minute

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 10%

VERIFICATION:
Parked regeneration

PROBABLE CAUSES:
1. Replace the fuel compensation pressure sensor.
2. Perform stationary regen.


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.