25% Discount for payments with Crypto Currency



Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1077 FMI 6 (MCM) Quantity Control Valve, Desired Current Does Not Match Actual Current

Posted by PerDiezel Solutions on

DESCRIPTION:
Quantity control valve (QCV) error.

MONITORED PARAMETER:
Quantity control valve.

TYPICAL ENABLING CONDITIONS:
RP closed loop control.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Current less than 200 mA.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 25%

VERIFICATION:
Engine Idle: One minute.

PROBABLE CAUSES:
1. Wiring between the ECM and the quantity control valve.
2. Quantity control valve.
3. ECM Failure.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1077 FMI 5 (MCM) Quantity Control Valve Current Too Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1077 FMI 4 (MCM) Quantity Control Valve (QCV) Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1077 FMI 3 (MCM) Quantity Control Valve (QCV) Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1073 FMI 5 (MCM) Jake Brake Stage 2 Circuit Failed Open
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1073 FMI 4 (MCM) Jake Brake Stage 2 Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1073 FMI 3 (MCM) Jake Brake Stage 2 Circuit Failed High