Detroit DD13 EPA07 (2007-09) Fault Code: SPN 411 FMI 3 (MCM) EGR Delta Pressure Sensor Circuit Failed High

Posted by PerDiezel Solutions on

DESCRIPTION:
EGR Delta Pressure Sensor Circuit High.

MONITORED PARAMETER:
EGR delta pressure sensor.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
2 seconds

DASH LAMPS:
1. CEL
2. MIL

ENGINE REACTION:
Derate 25%

VERIFICATION:
Engine Idle: One minute.

PROBABLE CAUSES:
1. EGR delta p sensor failure.
2. EGR delta p connector/harness.
3. EGR delta p pressure ports blocked.