25% Discount for payments with Crypto Currency



Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3471 FMI 5 (MCM) Hydrocarbon Doser Circuit Failed Open

Posted by PerDiezel Solutions on

DESCRIPTION:
Electronic Dosing Valve (EDV) circuit failed open.

MONITORED PARAMETER:
HC Doser Circuit

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
2 seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 10%

VERIFICATION:
Engine Idle

PROBABLE CAUSES:
1. Faulty wiring.
2. Faulty HC doser block.
3. Faulty MCM.


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.