Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intake temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually. Component LocationThe SCR intake temperature sensor is located in the...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Posted by PerDiezel Solutions on

Circuit DescriptionThe selective catalytic reduction (SCR) intake temperature sensor is used by the engine control module (ECM) to monitor the engine exhaust temperature entering the SCR catalyst. The ECM monitors the voltage on the signal pin and converts this to a temperature value. Component LocationThe SCR intake temperature sensor is located in the aftertreatment system. It is located between the diesel particulate filter and the SCR catalyst in the exhaust system. Conditions for Running the DiagnosticsThis diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually. Component LocationThe aftertreatment SCR temperature sensor module is mounted on...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually. Component LocationThe aftertreatment SCR temperature sensor module is mounted on...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually. Component LocationThe aftertreatment SCR temperature sensor module is mounted on...

Read more →