25% Discount for payments with Crypto Currency



cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1885 PID: PID 102 SPN: 3216 FMI: 4 Aftertreatment Intake Nox Sensor Circuit- Voltage Below Normal, or Shorted to Low Source

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system. Component LocationThe aftertreatment intake NOx sensor is mounted on the engine...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1887 PID: PID 2202 SPN: 3226 FMI: 4 Aftertreatment Outlet Nox Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Posted by PerDiezel Solutions on

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system. Component LocationThe aftertreatment outlet NOx sensor location can vary...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1894 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate

Posted by PerDiezel Solutions on

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code. Component LocationThe VGT actuator is located on the turbocharger bearing housing. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1896 PID: SID 146 SPN: 2791 FMI: 13 EGR Valve Controller- Out of Calibration

Posted by PerDiezel Solutions on

Circuit DescriptionThe exhaust gas recirculation (EGR) valve is controlled by a brushless motor located on top of the EGR valve. The EGR valve motor uses three different motor legs to move the valve through its range of motion. The ECM uses the EGR motor A, B, and C wires to command the EGR valve to the appropriate position in order to meet EGR flow targets.The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and...

Read more →


Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1897 PID: SID 27 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component

Posted by PerDiezel Solutions on

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code. Component LocationThe VGT actuator is located on the turbocharger bearing housing. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the...

Read more →