cumminz
Cummins ISB CM850 (2003-06) Fault Code: 2348 PID: 27 SPN: 27 FMI: 13 EGR valve failed automatic calibration procedure – out of calibration.
Posted by PerDiezel Solutions on
Cummins ISB CM850 (2003-06) Fault Code: 2348 PID: 27 SPN: 27 FMI: 13 EGR valve failed automatic calibration procedure – out of calibration. A possible cause of this fault could be an EGR valve assembly internal failure causing the EGR valve to not close fully. When troubleshooting inactive counts of this fault code, running the EGR Valve Test in INSITE? electronic service tool could help identify a stuck EGR valve. Possible repairs: 1)Replace the engine harness.2)Replace the EGR valve assembly.3)Replace the ECM. Cummins ISB CM850 (2003-06) Fault Code: 2347 (ISC) PID: SPN: 2790 FMI: 15 Turbocharger Compressor Outlet Air Temperature...
Cummins ISB CM850 (2003-06) Fault Code: 2349 PID: SID 146 SPN: 2791 FMI: 5 EGR Valve Control Circuit – Current Below Normal or Open Circuit. High voltage or open circuit detected at the EGR valve motor circuit.
Posted by PerDiezel Solutions on
Cummins ISB CM850 (2003-06) Fault Code: 2349 PID: SID 146 SPN: 2791 FMI: 5 EGR Valve Control Circuit – Current Below Normal or Open Circuit. High voltage or open circuit detected at the EGR valve motor circuit. The ECM monitors the voltage level of this circuit and logs a fault code if the voltage level indicates an open circuit or if a short circuit to voltage source is present. This fault is always set inactive when the keyswitch is turned on. If the fault condition reoccurs while the keyswitch is in the ON position, the fault code will be set...
Cummins ISB CM850 (2003-06) Fault Code: 235 PID: 111 SPN: 111 FMI: 1 Coolant Level – Data Valid but Below Normal Operational Range – Most Severe Level. Low engine coolant level detected.
Posted by PerDiezel Solutions on
Cummins ISB CM850 (2003-06) Fault Code: 235 PID: 111 SPN: 111 FMI: 1 Coolant Level – Data Valid but Below Normal Operational Range – Most Severe Level. Low engine coolant level detected. This fault code goes active when the coolant level inside the radiator top tank or surge tank drops below the sensor level. Fill the top tank with coolant. Possible repairs: 1)Add coolant to the engine. Cummins ISB CM850 (2003-06) Fault Code: 234 (Marine) PID: 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position – Data Valid but Above Normal Operational Range – Most Severe Level. Engine speed signal indicates...
Cummins ISB CM850 (2003-06) Fault Code: 2351 PID: SID 146 SPN: 2791 FMI: 4 EGR Valve Control Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at the EGR valve motor circuit.
Posted by PerDiezel Solutions on
Cummins ISB CM850 (2003-06) Fault Code: 2351 PID: SID 146 SPN: 2791 FMI: 4 EGR Valve Control Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at the EGR valve motor circuit. The ECM monitors the voltage level of the circuit and logs a fault code if the voltage level indicates a short to ground. This fault is always set inactive when the keyswitch is turned ON. If there is a failure of this circuit, the fault code will not be set active until the valve has been actuated. For these reasons, this troubleshooting tree must...
Cummins ISB CM850 (2003-06) Fault Code: 2352 PID: SID 146 SPN: 2791 FMI: 3 EGR Valve Control Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the EGR valve motor circuit.
Posted by PerDiezel Solutions on
Cummins ISB CM850 (2003-06) Fault Code: 2352 PID: SID 146 SPN: 2791 FMI: 3 EGR Valve Control Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the EGR valve motor circuit. The ECM monitors the voltage level of the circuit and logs a fault code if the voltage level indicates a short to ground. This fault is always set inactive when the keyswitch is turned ON. If there is a failure of this circuit, the fault code will not be set active until the valve has been actuated. For these reasons this troubleshooting tree must...