Cummins ISB CM850 (2003-06) Fault Code: 319 PID: 251 SPN: 251 FMI: 2 Real-Time Clock Power Interrupt – Data Erratic, Intermittent or Incorrect. Real-time clock lost power.

Posted by PerDiezel Solutions on

Cummins ISB CM850 (2003-06) Fault Code: 319 PID: 251 SPN: 251 FMI: 2 Real-Time Clock Power Interrupt – Data Erratic, Intermittent or Incorrect. Real-time clock lost power.

This fault indicates that the real-time clock in the ECM lost power. Possible causes for this fault are weak or failed real-time clock battery, failed wiring or connectors between the battery and ECM, or the engine is not equipped with a real-time clock battery and the vehicle battery power to the ECM is lost.

NOTE:If the Real Time Clock is supplied by the OEM via a CAN BUS and a battery backup is not used, then refer to the OEM wiring diagram. If this is the case, then check INSITE? electronic service tool, ?Advanced ECM Data – Real Time Clock Settings.? If the OEM supplies a Real Time Clock signal, then the address must be set according to the OEM wiring or the fault code will become active.

Possible repairs:

1)Replace the engine harness.
2)Repair or replace the real-time clock battery.

Cummins ISB CM850 (2003-06) Fault Code: 298 PID: 223 SPN: 1388 FMI: 4 Auxiliary Pressure Sensor Input 1 Circuit – Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Cummins ISB CM850 (2003-06) Fault Code: 297 PID: 223 SPN: 1388 FMI: 3 Auxiliary Pressure Sensor Input 1 Circuit – Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Cummins ISB CM850 (2003-06) Fault Code: 296 PID: 223 SPN: 1388 FMI: 14 Auxiliary Pressure Sensor Input 1 – Special Instructions
Cummins ISB CM850 (2003-06) Fault Code: 295 PID: 108 SPN: 108 FMI: 2 Barometric Pressure ?Data Erratic, Intermittent, or Incorrect. The barometric air pressure sensor is reading an erratic value at initial key-on.
Cummins ISB CM850 (2003-06) Fault Code: 294 PID: 441 SPN: 441 FMI: 4 Auxiliary Temperature Sensor Input 1 Circuit – Voltage Below Normal, or Shorted to Low Source. Low signal voltage detected at OEM auxiliary temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 293 PID: 441 SPN: 441 FMI: 3 Auxiliary Temperature Sensor Input 1 – Voltage Above Normal, or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.