Cummins ISB CM850 (2003-06) Fault Code: 272 (Auto) PID: SID 126 SPN: 1347 FMI: 3 High Fuel Pressure Solenoid Valve Circuit – Voltage Above Normal or Shorted to High Source. Electronic fuel control actuator shorted high.
This fault becomes active when the ECM detects an open in the electronic fuel control actuator circuit. Causes of this fault code are a short circuit to a positive voltage or an open circuit in the electronic fuel control actuator circuit. If there is high harness resistance, Fault Code 2311 could have high inactive counts. If the fault code is intermittent, look for causes of an intermittent open circuit such as loose pins and bad connections.
1)Replace the high-pressure fuel pump.
2)Repair or replace the engine harness, connector, or pins, if possible.
3)Replace the ECM.
Cummins ISB CM850 (2003-06) Fault Code: 271 (ISC – Auto) PID: SID 126 SPN: 1347 FMI: 4 High Fuel Pressure Solenoid Valve Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the fuel pump actuator circuit.
Cummins ISB CM850 (2003-06) Fault Code: 271 (Auto) PID: SID 126 SPN: 1347 FMI: 4 High Fuel Pressure Solenoid Valve Circuit – Voltage Below Normal or Shorted to Low Source. Electronic fuel control actuator shorted low.
Cummins ISB CM850 (2003-06) Fault Code: 269 PID: SID 217 SPN: 1195 FMI: 2 Antitheft Password Valid Indicator ? Data Erratic, Intermittent, or Incorrect. Engine ignition attempt without authorization from immobilizer anti-theft device.
Cummins ISB CM850 (2003-06) Fault Code: 268 PID: 94 SPN: 94 FMI: 2 Injector Metering Rail 1 Pressure – Data Erratic, Intermittent, or Incorrect. The ECM has detected that the fuel pressure signal is not changing.
Cummins ISB CM850 (2003-06) Fault Code: 253 PID: 98 SPN: 98 FMI: 1 Engine Oil Level ? Data Valid But Below Normal Operational Range ? Most Severe Level. Very low oil level has been detected by the oil level sensor.
Cummins ISB CM850 (2003-06) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the fan control circuit when commanded on.