Cummins ISB CM850 (2003-06) Fault Code: 2384 (ISB) PID: SID 27 SPN: 641 FMI: 4 VGT actuator driver circuit – voltage below normal, or shorted to low source.
A possible cause of this fault is the turbocharger actuator signal (+ or -) leads can be shorted to ground in the harness, motor, or the ECM.
Do not supply voltage of any kind to the exhaust gas recirculation (EGR) valve motor. This circuit uses a pulse-width-modulated signal and direct voltage can permanently damage the motor.
Possible repairs:
1)Replace the turbocharger.
2)Repair or replace the engine harness.
3)Replace the ECM.
4)The removal and reinstallation of the connector may correct the fault.
Cummins ISB CM850 (2003-06) Fault Code: 2383 PID: SID 27 SPN: 641 FMI: 5 Variable Geometry Turbocharger actuator circuit – current below normal, or open circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2382 PID: SPN: 2795 FMI: 4 Turbocharger position sensor circuit – shorted low. Low signal voltage detected at the turbocharger position sensor circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2381 PID: SPN: 2795 FMI: 4 Turbocharger position sensor circuit – shorted high. High signal voltage detected at the turbocharger position sensor circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at the fan control circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2376 PID: 412 SPN: 412 FMI: 2 Recirculation Exhaust Gas (EGR) Temperature Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the EGR temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2375 PID: 412 SPN: 412 FMI: 3 EGR Temperature Sensor Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the EGR temperature sensor circuit.