25% Discount for payments with Crypto Currency



Cummins ISB CM850 (2003-06) Fault Code: 2366 PID: SID 28 SPN: 1072 FMI: 3 Engine Brake Actuator Circuit #1 – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at the engine brake solenoid number 1 signal circuit.

Posted by PerDiezel Solutions on

Cummins ISB CM850 (2003-06) Fault Code: 2366 PID: SID 28 SPN: 1072 FMI: 3 Engine Brake Actuator Circuit #1 – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at the engine brake solenoid number 1 signal circuit.

Possible causes:

1)Open circuit in the engine harness, brake harness, or engine brake solenoids
2)Short to voltage source in the engine harness
3)Failed ECM.

Possible repairs:

1)Replace the engine brake solenoid.
2)Replace the ECM.
3)Repair or replace the engine harness.

Cummins ISB CM850 (2003-06) Fault Code: 2363 PID: SID 29 SPN: 1073 FMI: 4 Engine Brake Actuator Circuit #2 – Voltage Below Normal or Shorted to Low Source. Low voltage detected at the engine brake solenoid number 2 signal circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2362 PID: SID 28 SPN: 1072 FMI: 4 Engine Brake Actuator Circuit #1 – Voltage Below Normal or Shorted to Low Source. Low voltage detected at the engine brake solenoid number 1 signal circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2359 PID: 411 SPN: 411 FMI: 0 Exhaust Gas Recirculation (EGR) Differential Pressure Sensor – Data Valid but Above Normal Operating Range – Moderately Severe Level. EGR differential pressure sensor failed automatic calibration procedure or EGR differential pressure reading not valid for engine operating conditions.
Cummins ISB CM850 (2003-06) Fault Code: 2357 PID: SID 146 SPN: 2791 FMI: 7 Exhaust Gas Recirculation (EGR) Valve Control – Mechanical System Not Responding Properly or Out of Adjustment. EGR valve motor does not respond or is slow to respond.
Cummins ISB CM850 (2003-06) Fault Code: 2353 PID: SID 146 SPN: 2971 FMI: 6 Exhaust Gas Recirculation (EGR) valve control circuit – current above normal or grounded circuit. Excess current detected at the EGR valve motor output circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2352 PID: SID 146 SPN: 2791 FMI: 3 EGR Valve Control Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the EGR valve motor circuit.