Cummins ISB CM850 (2003-06) Fault Code: 2216 (ISC) PID: 94 SPN: 94 FMI: 1 Fuel Pump Delivery Pressure High – Data Valid but Above Normal Operational Range – Moderately Severe Level. The ECM has detected that fuel pressure is higher than commanded pressure.
A fuel pump actuator with excessive leakage or a damaged inboard o-ring will result in high fuel rail pressures at idle or light load.
If the fuel pump actuator exhibits excessive leakage, it is possible that the fuel rail pressure will reach the opening pressure of the fuel rail pressure relief valve and Fault Code 449 may also become active.
Possible repairs:
1)Replace the fuel gear pump assembly.
2)Replace the damaged o-ring.
3)Replace the fuel pump actuator.
Cummins ISB CM850 (2003-06) Fault Code: 2216 (ISB) PID: 94 SPN: 94 FMI: 0 Fuel pump delivery pressure – data valid but above normal operational range – moderately severe level. The ECM has detected fuel pressure in the fuel rail that is higher than the commanded pressure.
Cummins ISB CM850 (2003-06) Fault Code: 2215 (ISC) PID: 94 SPN: 94 FMI: 0 Fuel Pump Delivery Pressure Low – Data Valid but Below Normal Operational Range – Moderately Severe Level. The ECM has detected that fuel pressure is lower than commanded pressure.
Cummins ISB CM850 (2003-06) Fault Code: 2215 (ISB) PID: 94 SPN: 94 FMI: 1 Fuel Pump Delivery Pressure – Data Valid but Below Normal Operational Range – Moderately Severe Level. The ECM has detected the fuel pressure in the fuel rail is lower than the commanded performance.
Cummins ISB CM850 (2003-06) Fault Code: 2195 PID: SID 51 SPN: 703 FMI: 14 Auxiliary Equipment Sensor Input Engine Protection Critical – Special Instructions. OEM switch signal on the OEM harness indicates engine protection condition.
Cummins ISB CM850 (2003-06) Fault Code: 2186 PID: SID 232 SPN: FMI: 4 Sensor Supply Voltage 4 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at +5 VDC sensor supply circuit to the accelerator pedal position sensor.
Cummins ISB CM850 (2003-06) Fault Code: 2185 PID: SID 232 SPN: FMI: 3 Sensor Supply Voltage 4 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at +5 volt sensor supply circuit to the accelerator pedal position sensor.