Cummins ISB CM850 (2003-06) Fault Code: 147 PID: 91 SPN: FMI: 1 Accelerator Pedal or Lever Position 1 Sensor Circuit Frequency – Data Valid but Below Normal Operational Range – Most Severe Level.

Posted by PerDiezel Solutions on

Cummins ISB CM850 (2003-06) Fault Code: 147 PID: 91 SPN: FMI: 1 Accelerator Pedal or Lever Position 1 Sensor Circuit Frequency – Data Valid but Below Normal Operational Range – Most Severe Level. A frequency of less than 100 HZ has been detected at the frequency throttle input to the ECM.

The frequency throttle can be used in conjunction with a voltage throttle or by itself.

Possible causes:

1)Open circuit in the frequency throttle signal wire.
2)Shorted to ground frequency throttle signal wire.
3)Failed frequency throttle.
4)Incorrect frequency throttle reference (input) voltage.

Possible repairs:

1)Repair or replace the frequency throttle.
2)Repair or replace the frequency throttle reference (input) circuit.
3)Repair or replace the OEM harness.
4)Replace the ECM.

Cummins ISB CM850 (2003-06) Fault Code: 146 (Marine) PID: 100 SPN: 110 FMI: 0 Engine Coolant Temperature – Data Valid but Above Normal Operational Range – Moderately Severe Level. Engine coolant temperature signal indicates engine coolant temperature is above engine protection warning limit.
Cummins ISB CM850 (2003-06) Fault Code: 146 (Auto) PID: 110 SPN: 110 FMI: 0 Engine Coolant Temperature – Data Valid but Above Normal Operational Range – Moderately Severe Level. Engine coolant temperature signal indicates engine coolant temperature is above engine protection warning limit.
Cummins ISB CM850 (2003-06) Fault Code: 145 (Marine) PID: 110 SPN: 110 FMI: 4 Engine Coolant Temperature 1 Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at engine coolant temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 145 (Auto) PID: 110 SPN: 110 FMI: 4 Engine Coolant Temperature 1 Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at engine coolant temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 144 (Marine) PID: 110 SPN: 110 FMI: 3 Engine Coolant Temperature 1 Sensor Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at engine coolant temperature circuit.
Cummins ISB CM850 (2003-06) Fault Code: 144 (Auto) PID: 110 SPN: 110 FMI: 3 Engine Coolant Temperature 1 Sensor Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at engine coolant temperature circuit.

PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.