Cummins ISB CM850 (2003-06) Fault Code: 1242 PID: SPN: 91 FMI: 2 Accelerator Pedal or Lever Position Sensor Number 1 and Number 2 – Data Erratic, Intermittent, or Incorrect. Accelerator position sensors numbers 1 and 2 are reading different values.
Newer engines use two throttle position sensors to determine the throttle position. Older throttle pedals used a single throttle position sensor and an idle validation switch. If Fault Codes 132 and 1241 are active when the accelerator pedal is in the idle position and Fault Code 132 goes inactive and Fault Code 1239 goes active when the throttle is depressed, the incorrect throttle pedal has been installed in the vehicle. A throttle pedal with two acceleration position sensors should be installed.
This fault code becomes active when the accelerator position sensor number 1 and accelerator position sensor number 2 are not reading the same value.
1)Failed accelerator pedal position sensor 1 or failed accelerator pedal position sensor number 2.
2)Accelerator pedal position sensor number 1 and accelerator pedal position sensor number 2 signal wires are shorted.
1)Repair or replace the OEM harness.
2)Replace the accelerator pedal.
Cummins ISB CM850 (2003-06) Fault Code: 1241 PID: SPN: 2623 FMI: 4 Accelerator Pedal or Lever Position Sensor 2 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at accelerator pedal position number 2 signal circuit.
Cummins ISB CM850 (2003-06) Fault Code: 1239 PID: SPN: 2623 FMI: 3 Accelerator Pedal or Lever Position Sensor 2 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at accelerator pedal position number 2 signal circuit.
Cummins ISB CM850 (2003-06) Fault Code: 1229 PID: SID 27 SPN: 2795 FMI: 2 VGT Position Sensor – Data erratic, intermittent, or incorrect. Intermittent variable geometry turbocharger (VGT) position information is being received by the electronic control module (ECM).
Cummins ISB CM850 (2003-06) Fault Code: 1228 PID: 27 SPN: 27 FMI: 2 EGR Valve Position – Data erratic, intermittent, or incorrect. Intermittent EGR position information is being received by the electronic control module (ECM).
Cummins ISB CM850 (2003-06) Fault Code: 1145 PID: SID 6 SPN: 656 FMI: 7 Injector Solenoid Driver Cylinder 6 – Mechanical System Not Responding Properly or Out of Adjustment. Unintended fueling detected in cylinder Number 6.
Cummins ISB CM850 (2003-06) Fault Code: 1144 PID: SID 5 SPN: 655 FMI: 7 Injector Solenoid Driver Cylinder 5 – Mechanical System Not Responding Properly or Out of Adjustment. Unintended fueling detected in cylinder Number 5.