CAT 3406E (Prefix 1MM or 2WS) Fault Code: 29 PID: SPN: 30 FMI: 13 PTO Throttle out of calibration

Posted by PerDiezel Solutions on

The Engine Control Module (ECM) detects the following conditions:

•The duty cycle of the signal for the PTO throttle is less than 5 percent or more than 95 percent for more than two seconds.
•The PTO Configuration is programmed to “Remote Throttle”.
•The ECM has been powered for at least three seconds.

Probable Causes:

1) ECM Connection/Harness
2) Accelerator Position Sensor
3) Accelerator Position Sensor Harness
4) ECM Failure

CAT 3406E (Prefix 1MM or 2WS) Fault Code: 29 PID: SPN: 30 FMI: 8 PTO Throttle signal invalid
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 28 PID: SPN: 91 FMI: 13 Throttle Sensor out of calibration
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 27 PID: SPN: 110 FMI: 4 Coolant Temperature voltage low
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 27 PID: SPN: 110 FMI: 3 Coolant Temperature voltage high
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 26 PID: SPN: 108 FMI: 4 Atmospheric Pressure voltage low
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 26 PID: SPN: 108 FMI: 3 Atmospheric Pressure voltage high