25% Discount for payments with Crypto Currency



Allison

Allison 1000 & 2000 Gen 5 Fault Code:P0979 Shift Solenoid 3 (SS3) Control Circuit – Low

Posted by PerDiezel Solutions on

CIRCUIT DESCRIPTION:SS3 is a Normally Closed (N/C) solenoid that provides control main pressure to stroke Shift Valve 3 (SV3) to attain a particular range needed for the next upshift or downshift. A pressure switch is located at the end of the shift valve to send valve position status back to the TCM. The TCM sends control current to SS3 from High Side Driver 2 (HSD2) via wire 171. HSD2 is continuously on unless the TCM detects a fault condition. The TCM regulates the amount of current to SS3 by switching the low side driver on and off. Wire 151 completes...

Read more →


Allison 1000 & 2000 Gen 5 Fault Code:P097A Shift Solenoid 1 (SS1) Control Circuit – Open

Posted by PerDiezel Solutions on

CIRCUIT DESCRIPTION:SS1 is a Normally Closed (N/C) solenoid that provides control main pressure to stroke Shift Valve 1 (SV1) to attain a particular range needed for the next upshift or downshift. A pressure switch is located at the end of the shift valve to send valve position status back to the TCM. The TCM sends control current to SS1 from High Side Driver 2 (HSD2) via wire 171. HSD2 is continuously on unless the TCM detects a fault condition. The TCM regulates the amount of current to SS1 by switching the low side driver on and off. Wire 152 completes...

Read more →


Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open

Posted by PerDiezel Solutions on

CIRCUIT DESCRIPTION:Shift Solenoid 2 (SS2) is a Normally Closed (N/C) solenoid that provides control main pressure to stroke Shift Valve 2 (SV2) to attain a particular range needed for the next upshift or downshift. A pressure switch is located at the end of the shift valve to send valve position status back to the TCM. The TCM sends control current to SS2 from High Side Driver 2 (HSD2) via wire 171. HSD2 is continuously on unless the TCM detects a fault condition. The TCM regulates the amount of current to SS2 by switching the low side driver on and off....

Read more →


Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open

Posted by PerDiezel Solutions on

CIRCUIT DESCRIPTION:SS3 is a Normally Closed (N/C) solenoid that provides control main pressure to stroke Shift Valve 3 (SV3) to attain a particular range needed for the next upshift or downshift. A pressure switch is located at the end of the shift valve to send valve position status back to the TCM. The TCM sends control current to SS3 from High Side Driver 2 (HSD2) via wire 171. HSD2 is continuously on unless the TCM detects a fault condition. The TCM regulates the amount of current to SS3 by switching the low side driver on and off. Wire 151 completes...

Read more →


Allison 1000 & 2000 Gen 5 Fault Code:P0980 Shift Solenoid 3 (SS3) Control Circuit – High

Posted by PerDiezel Solutions on

CIRCUIT DESCRIPTION:SS3 is a Normally Closed (N/C) solenoid that provides control main pressure to stroke Shift Valve 3 (SV3) to attain a particular range needed for the next upshift or downshift. A pressure switch is located at the end of the shift valve to send valve position status back to the TCM. The TCM sends control current to SS3 from High Side Driver 2 (HSD2) via wire 171. HSD2 is continuously on unless the TCM detects a fault condition. The TCM regulates the amount of current to SS3 by switching the low side driver on and off. Wire 151 completes...

Read more →


PerDieselSolution Logo

WARNING!

PerDieselSolution informs all customers and visitors that fake websites and copied domains are being used by scammers.

Please make sure you are visiting our ONLY official website:

perdieselsolution.com

We publish this notice to protect our customers from fraudulent stores and unofficial sellers.