Allison
Allison WTEC II Fault Code: 54 PID: SPN: 95 FMI: Oncoming ratio test (after shift), N3 to 5
Posted by PerDiezel Solutions on
Main code 54 indicates a failed oncoming ratio test. N3?5 shift The ratio test after a shift is failed when the ECU has commanded the end of a shift and has not seen the transmission shift into the target range (comparing turbine and output speeds). Erratic readings from speed sensors are a likely cause of an oncoming ratio test failure. If conditions for a shift still exist, the shift will be retried one more time. If the ratio test is still not met, a code is logged and the DO NOT SHIFT response is commanded. If the code is set...
Allison WTEC II Fault Code: 54 PID: SPN: 96 FMI: Oncoming ratio test (after shift), N4 to 6
Posted by PerDiezel Solutions on
Main code 54 indicates a failed oncoming ratio test. N4?6 shift The ratio test after a shift is failed when the ECU has commanded the end of a shift and has not seen the transmission shift into the target range (comparing turbine and output speeds). Erratic readings from speed sensors are a likely cause of an oncoming ratio test failure. If conditions for a shift still exist, the shift will be retried one more time. If the ratio test is still not met, a code is logged and the DO NOT SHIFT response is commanded. If the code is set...
Allison WTEC II Fault Code: 54 PID: SPN: 97 FMI: Oncoming ratio test (after shift), 2 to R (2 to NNC to R)
Posted by PerDiezel Solutions on
Main code 54 indicates a failed oncoming ratio test. NVL?Reverse shift The ratio test after a shift is failed when the ECU has commanded the end of a shift and has not seen the transmission shift into the target range (comparing turbine and output speeds). Erratic readings from speed sensors are a likely cause of an oncoming ratio test failure. If conditions for a shift still exist, the shift will be retried one more time. If the ratio test is still not met, a code is logged and the DO NOT SHIFT response is commanded. If the code is set...
Allison WTEC II Fault Code: 54 PID: SPN: XY FMI: Oncoming ratio test, X to Y
Posted by PerDiezel Solutions on
Main code 54 indicates a failed oncoming ratio test. X to Y shift The ratio test after a shift is failed when the ECU has commanded the end of a shift and has not seen the transmission shift into the target range (comparing turbine and output speeds). Erratic readings from speed sensors are a likely cause of an oncoming ratio test failure. If conditions for a shift still exist, the shift will be retried one more time. If the ratio test is still not met, a code is logged and the DO NOT SHIFT response is commanded. If the code...
Allison WTEC II Fault Code: 55 PID: SPN: 07 FMI: Oncoming C3PS test, L to R
Posted by PerDiezel Solutions on
Main code 55 indicates the C3 clutch is the oncoming clutch in a shift and the C3 pressure switch did not close at the end of the shift. Oncoming C3PS (after shift), L?R shift When this code is set, the DO NOT SHIFT response and Neutral with No Clutches is commanded. On the N1 to R shift the transmission is commanded to the previous range. Additional codes could be logged for other shifts where ?X? indicates the range from and ?Y? indicates the range to. Main code 55 can also be caused by the EEPROM being calibrated for a close...